Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
RSBO (Impr.) ; 8(3): 287-293, Jul.-Sep. 2011. ilus, tab
Article in English | LILACS | ID: lil-720316

ABSTRACT

Introduction and objective: Glass ionomer cement, which was first introduced in Dentistry in 1972, presents good qualities such as aesthetics, fluoride release and adhesion to dental tissues. Because of its preventive characteristics regarding to dental caries, glass ionomer cement has been used for Atraumatic Restorative Treatment (ART), as reported by Frencken and Holmgren 6, meeting the principles announced by the World Health Organization (WHO) for application to large population groups without regular access to dental care. Material and methods: In this present study, the abrasive wear strength of two glass-ionomer cements (Vidrion R® and ChemFlex®) was evaluated through toothbrushing machine. Classic® toothbrushes with soft bristles and Sorriso® dentifrice were also used for the study. Results: Student-t test showed significant difference between both groups, with tobs value = 9.4411 at p < 0.05. Conclusion: It can be concluded that the wear rate caused by toothbrush/dentifrice was higher for Vidrion R® (52.00 mg) than ChemFlex® (5.57 mg).

2.
Bauru; s.n; 2011. 91 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-865836

ABSTRACT

Neste estudo, foi avaliada a resistência ao desgaste abrasivo de uma resina composta, através de três diferentes métodos: do disco retificado, por escovação e do nanodurômetro. Nos dois primeiros métodos, foram utilizados 20 espécimes da resina Filtek Z250 (10 da cor Incisal e 10 da cor C4, ambos fotopolimerizados por 30 segundos cada) e 10 de polimetilmetacrilato (PMMA), atuando estes últimos como padrão de referência. Para os ensaios com o nanodurômetro, foi utilizado apenas um espécime de cada cor, assim como um único de PMMA, em cujas superfícies planas foram efetuadas sete medições, o que foi considerado equivalente a sete espécimes. No método do disco retificado, cada espécime de resina composta era confeccionado diretamente numa cavidade semicircular, localizada na periferia de um disco-suporte; os espécimes de PMMA consistiam em discos constituídos exclusivamente por este material; o desgaste de cada espécime era promovido por um disco de porcelana e seu conseqüente deslocamento era detectado por um palpador; assim, a taxa de desgaste era estabelecida, expressa em milímetros cúbicos por newton por segundo (mm3/N.s). No método de escovação, cada espécime cilíndrico ficava preso numa placa metálica, a qual era fixada no interior da máquina de escovação; sua perda de massa (em miligramas) era verificada através de uma balança analítica. No método do nanodurômetro, existiu apenas um espécime ci líndrico para cada condição, em cuja face plana superior eram feitos sete sulcos (equivalentes a sete espécimes); o coeficiente de atrito permitia estabelecer a respectiva resistência ao desgaste. Para cada método utilizado, os dados foram tratados estatisticamente, através de análise de variância (ANOVA) e de teste de Tukey. Pôde-se concluir que, através do disco retificado, a taxa de desgaste (em mm3/N.s) dos materiais foi: Incisal (0,6807) > C4 (0,5012) > PMMA (0,1439); que, através da escovação, a taxa de desgaste (em mg) foi de 5,40 para...


Abrasive wear of a composite resin, using three different methods (ground disc, toothbrushing and nanodurometer). The aim at this study was to evaluate the resistance to abrasive wear of a composite resin, using three different methods: ground disc, toothbrushing and nanodurometer. At the first two methods were employed 20 specimens of Filtek Z250 composite resin (10 of Incisal and 10 of C4, both the colors cured for 30 seconds each one) and 10 of polymethylmethacrylate (PMMA), the latter acting as a reference standard. For the tests with the nanodurometer it was used only one specimen of each color, as well as just one of PMMA, in whose flat surfaces seven measurements were made, what was considered equivalent to seven specimens. At the ground disc method, each composite resin specimen was directly made on a semicircular cavity located on the periphery of a supporting disc; PMMA specimens consisted of discs made up exclusively with this material; the wear of each specimen was promoted by a ceramic disc and its consequent displacement was detected by a sensor; thus, the wear rate was established, expressed in cubic millimeters per newton per second (mm3/N.s). At the toothbrushing method, each cylindrical specimen was trapped in a metal plate, which was fixed inside the machine brushing; its weight loss (in milligrams) was verified by an analytical balance. At the nanodurometer method, there was only one cylindrical specimen for each condition, in whose flat upper face seven grooves were made (what was equivalent to seven specimens); the coefficient of friction was used to establish its wear resistance. For each method, data were statistically analyzed by ANOVA and Tukey's test. It could be concluded that, by ground disc method, materials wear rate (in mm3/N.s) was Incisal (0.6807) > C4 (0.5012) > PMMA (0.1439); by brushing method, materials wear rate (in mg) was 5.40 for Incisal, 9.35 for C4 and 5.88 for PMMA, without significant difference...


Subject(s)
Tooth Abrasion/etiology , Toothbrushing/adverse effects , Composite Resins/chemistry , Hardness Tests , Materials Testing , Polymerization , Surface Properties , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL